Machine status: 1. Based on the visual inspection, no obvious signs of cracking, deformation, or damage were found on the machine enclosure, working axes, hydraulic system, in-process measuring system, cooling system, filtration unit, or other visible components. 2. The machine can be powered on, and the power supply has been confirmed to be normal. However, the axis parameters and program data have been lost, so it is currently not possible to verify whether the individual axes and overall machine movements are functioning properly. 3. After power-up, the axis positions, coordinates, machining programs, and other related data Kecez Dfn Aezmu Hn Aodt displayed on the screen all appear as question marks (“?”). The NCU battery and UPS battery were replaced, but the condition remained unchanged. 4. After power-up, a large number of error messages appear on the diagnostic page, including A1-axis encoder errors, input voltage errors, control module errors, cross-error compensation errors, and other related alarms. 5. According to the customer, the handwheel is damaged and needs to be replaced with a new one. The laser printer may also be defective and requires further inspection and confirmation. 6. The hydraulic oil, cutting oil, coolant, lubricating oil, and other fluids have been stored or used for an extended period and should be replaced with new fluids. 7. The pneumatic system hoses/pipes should be inspected for aging, cracks, or damage. Replacement will be required if any deterioration or leakage is found.

Характеристики

Производитель
Gleason-Pfauter
Модель
P1200G
Год выпуска
2010
Состояние
repair required (used)